CPHI Milan 2
CPHI Milan newsletter
PCI High Potent Manufacturing
LB Bohle – 10.06.2025
Temax_Krautz

Current Edition

Current Edition

Subsection - CDMO

Examining how innovative technologies, integrated manufacturing approaches and AI are shaping manufacturing.

Continue reading

Subsection - Injectables

Exploring advances in injectable drug delivery and sterile manufacturing, designed to improve patient-centric delivery.

Continue reading

Subsection - Neurodegenerative Diseases

Exploring emerging approaches to neurodegenerative disease research and treatment.

Continue reading

Subsection - Nasal & Pulmonary

Highlighting how advances in nasal and pulmonary drug delivery, formulation, devices and analytics are enabling more complex therapies.

Continue reading

Advertisement

CPHI 2027
DDL 2026

Advertisement

Nipro August 26

Advertisement

Merxin March 2026

Advertisement

Aurisco 300×250

Advertisement

Lifecore Biomedical

Beyond Propellant Replacement: A More Intelligent Development Pathway for Low-GWP pMDIs

The transition to low-global-warmingpotential (low-GWP) propellants is one of the most significant changes to pressurised metered dose inhaler (pMDI) development in decades. The environmental driver is clear. The pharmaceutical challenge is considerably more complex.

A pMDI is not simply a drug formulation packaged with a propellant. It is a coupled formulation – container closure – device system in which the propellant contributes directly to metering, atomisation, plume formation, evaporation, and aerodynamic behaviour. Changing one of the fundamental physical components of that system can therefore affect formulation behaviour, device interactions, aerosol generation, dose delivery, regional deposition, and ultimately the evidence required to demonstrate acceptable product performance. The EMA’s current lowGWP pMDI guidance reflects that breadth, covering quality, non-clinical, and clinical considerations rather than treating propellant replacement as a narrow formulation change.

The development objective is therefore not simply to demonstrate that a reformulated product produces acceptable analytical results. It is to understand whether the aerosol journey remains appropriate from device to patient. That requires a broader set of questions: How does it fly? Where does it land? What arrives? These are connected questions, but they are not answered by the same measurement. That three-part framework sits at the centre of the current Proveris low-GWP scientific strategy.

The low-GWP transition creates an opportunity to reconsider when those questions are asked. Rather than relying heavily on a full, expensive, compendial test package early in development when formulations, valves, actuators, and instructions for use may still be changing, a more efficient strategy is to generate a greater density of rapid, mechanistic, and comparative information first. More resource-intensive testing can then be concentrated on candidates that have already been characterised and understood. This is the principle behind Proveris by Design™ (PbD): generate actionable evidence early, follow the mechanism, add realism where its required, and confirm the selected product rigorously.

Low-GWP Reformulation Changes a Connected System

The scientific challenge begins with aerosol generation. Following actuation, a metered volume of pressurised formulation passes through the valve and actuator and undergoes rapid pressure reduction, flash evaporation, and atomisation. The aerosol then continues to evolve after leaving the device as droplets or particles interact with surrounding air and volatile components evaporate. Low-GWP propellants do not have identical thermophysical properties to the currently used HFA-134a. Reviews of HFA-152a and HFO1234ze(E) have highlighted these differences and their potential consequences for formulation and atomisation. Recent experimental studies reinforce the point. Duke and colleagues compared solution pMDIs formulated with HFA-134a, HFA-152a, and HFO-1234ze(E) using APSD, laser diffraction, and high-speed imaging. In the systems studied, HFA-152a produced greater actuator and throat deposition and different plume behaviour, while HFO-1234ze(E) was more similar to HFA-134a in APSD but still showed differences in plume development. A subsequent suspension study demonstrated that the presence of suspended drug further modifies the relationship between propellant properties and spray structure, including flash-evaporation behaviour and plume width.

Advertisement

MedPharm 16/07

Advertisement

Biopharma group march 2026

Advertisement

Silgan March 2026

Advertisement

Terumo 06/26

Advertisement

Scott Pharma – 25.03.2025

Advertisement

Bespak

Advertisement

Solstice

Advertisement

Bachem skyscraper
Tjoapack
Aptar – 08/01/2026